MODEL | SPH-100G | SPH-100T | SPH-200G |
Type | Filling | Filling | Non-Filling |
Measuring Range | 0-14.00pH | 0 ̴ 14.00 pH | 0 ̴ 14.00 pH |
Conductivity of liquid | over than 100 0㎲/㎝ | over than 100 us/cm | over than 100 us/cm |
Temperature | 5-60°C | 5 – 60˚C | 0 – 90˚C |
Pressure | Using HOLDER filled with KCL It’s filled by atomospheric pressure | Using HOLDER filled with KCL It’s filed by atomospheric pressure | Less than max 1kg/cm² |
Reference Electrode | Ag/AgCl | Ag/AgCI | Ag/AgCI |
Junction | sleeve | sleeve | sleeve |
Zero Potential | 7.00pH±0.01pH | 7.00pH ± 0.01pH | 7.00pH ± 0.01pH |
Materials | glass | glass | glass |
Dimensions | Ø12 X 155mm | Ø12 X 155mm | Ø12 X 155mm |
Cable Length | 5M(Standard) | 5m (Standard) | 5m (Standard) |
Connector | Y-Terminal Type | Y-Terminal type | Y-Terminal type |
Connector | Y-Terminal type | Available | Y-Terminal type |
MODEL | SPH-200V | SPH-200T |
Type | Non-Filling | Non-Filling |
Measuring Range | 0 ̴ 14.00 pH | 0 ̴ 14.00 pH |
Conductivity of liquid | over than 200 us/cm | over than 200 us/cm |
Temperature | 0 – 80˚C | 0 – 90˚C |
Pressure | Less than max 0.5kg/cm² | Less than max 1kg/cm² |
Reference Electrode | Ag/AgCI | Ag/AgCI |
Junction | Ceramic | sleeve |
Zero Potential | 7.00pH ± 0.01pH | 7.00pH ± 0.01pH |
Materials | PC Housing | glass |
Dimensions | Ø12 X 155mm | Ø12 X 155mm |
Cable Length | 5m (Standard) | 5m (Standard) |
Connector | Y-Terminal type | Y-Terminal type |
Connector | Y-Terminal type | Available |
SAMSAN SOR-300G,SOR-400G,SOR-400V
ITEM | ORP electrode | ORP electrode | ORP electrode |
MODEL | SOR-300G | SOR-400G | SOR-400V |
Type | Filling | Non-Filling | Non-Filling |
Measuring Range | ± 1500 mV | ± 1500 mV | ± 1500 mV |
Conductivity of liquid | over than 100 us/cm | over than 200 us/cm | over than 200 us/cm |
Temperature | 0 – 60˚C | 0 – 90˚C | 0 – 80˚C |
Pressure | Using HOLDER filled with KCL It’s filed by atomospheric pressure | Less than max 1kg/cm² | Less than max 0.5kg/cm² |
Reference Electrode | Ag/AgCI | Ag/AgCI | Ag/AgCI |
Junction | sleeve | sleeve | Caramic |
Zero Potential | 0 mV ± 1 mV | 0 mV ± 1 mV | 0 mV ± 1 mV |
Materials | glass | glass | PC Housing |
Dimensions | Ø12 X 155mm | Ø12 X 155mm | Ø12 X 155mm |
Cable Length | 5m (Standard) | 5m (Standard) | 5m (Standard) |
Connector | Y-Terminal type | Y-Terminal type | Y-Terminal type |