Cable Entry Every cabtyre cable has an anti-wicking block at the cable entry section on the pump which has flowed in between each strand of the conductor.
Cable Entry TSURUMI Every cabtyre cable has an anti-wicking block at the cable entry section on the pump. This mechanism is such that a part of each conductor is stripped back and the part is sealed by molded rubber or epoxy potting which has flowed in between each strand of the conductor. This unique feature prevents wicking along the strand of the conductor itself.
U, Y | Red wire |
V, Z | White wire |
W, X | Black wire |
Ground | Green wire |
Motor Protector (MTP) | Yellow wire |
Leak Sensing Electrode | White wire
(small) |