Facebook
Twitter
Email
Print

SANXIN SX-700 Series

FEATURES

  • Special water-proof connector which four different electrodes (pH, ORP. Conductivity, DO) can be plugged into, ability of the meter to recognize automatically those electrodes.
  • Advanced pH measurement mode Automatic calibration, options of three series of pH buffer solution Ability to set two special pH measurement modes of high purity water and ammonia added purity water. 2503DT pure water pH electrode with a built-in temperature probe, applied in pH measurement of high purity water.
  • IP57 water-proof, applied even under the difficult conditions.
  • The most advanced conductivity measurement mode Adopts one common two-ring conductivity electrode(k=1 built-in temperature probe), only one-point calibration, measurement range: 0.54S/cm-200mS/cm, accuracy: less than 1.5%FS. Automatic switches of range, automatic non-linear temperature compensation for high purity water DJS-0.1/T conductivity electrode (k=0.1. built-in temperature probe, with a flow tube assembly). applied for measurement of the high purity water less than 14S/cm. Ability to switch among Conductivity, TDS, Salinity and Resistivity.
  • Mobile Laboratory
  • meter, electrode, standard solution and other accessories are all in a portablecase.
  • Advanced Dissolved Oxygen measurement mode DO 500 Dissolved Oxygen electrode can simultaneously measure DO, Conductivity and Temperature to realize automatic salinity compensation for DO measurement. Polarogram type DO electrode with special electrode calibration sets, electrode polarization for only 3 to 5 minutes.

 

Technical Parameters

Single parameter SX711 Portable pH Meter
SX712 Portable ORP Meter
SX713 Portable Conductivity/TDS/Salinity/Resistivity Meter
SX716 Portable Dissolved Oxygen Meter
Double parameter SX721 Portable pH/ORP Meter
SX723 Portable pH/Conductivity Meter
SX725 Portable pH/Dissolved Oxygen Meter
SX726 Portable Conductivity/Dissolved Oxygen Meter
Multi-parameter SX731 Portable pH/ORP/Conductivity Meter
SX736 Portable pH/Conductivity/Dissolved Oxygen Meter
SX751 Portable pH/ORP/Conductivity/Dissolved Oxygen Meter

 

SANXIN SX-700 Series Specifications

Model SANXIN SX711 SANXIN sX712 SANXIN SX713 SANXIN SX716 SANXIN SX721 SANXIN SX723 SANXIN SX725 SANXIN SX726 SANXIN SX731 SANXIN SX736 SANXIN SX751
Measurement Parameters pH
mV
Temp.
ORP Cond.
TDS
Sal.
Res.
Temp.
DO
Temp.
pH
ORP
Temp.
pH
mV
Cond.
TDS
Sal.
Res.
DO
Temp.
pH
mV
DO
Temp.
Cond.
TDS
Sal.
Res.
DO
Temp.
pH
ORP
Cond.
TDS
Sal.
Res.
Temp.
pH
mV
Cond.
TDS
Sal.
Res.
DO
Temp.
pH
ORP
Cond.
TDS
Sal.
Res.
DO
Temp.
pH v v v v v v v
Range (-2.0  ̴19.99) pH
Accuracy ± 0.1 pH
Automatic Calibration (1  ̴3) point
ATC (0  ̴100)˚C
mV(oRP) v v v v v v v v
Range ± 1999 mV
Accuracy ± 0.1% FS
Conductivity v v v v v v
Range Conductivity:
(0.00-19.99) μS/cm
(20.00-199.9) μS/cm
(200-1999) μS/cm
(2.00-19.99)mS/cm
(20.0-199.9) mS/cm
TDS:(0-100) g/L
TDS:(0-100) g/L
Sal.:(0-100) ppt
Res:(0-100) MΩ ·cm
Accuracy ± 1.0% FS
Automatic Calibration 1 point
ATC (0  ̴50)˚ C
Dissolved Oxygen v v v v v
Range (0  ̴40.00) mg/L
(ppm)
(0  ̴199.9)%
Accuracy ± 1.0% FS
ATC (0  ̴45)˚ C
Automatic Salinity Compensation (0  ̴45) ppt
Manual Air Pressure Compensation (66  ̴200)kPa