SAMSAN SPH-100G,SPH-100T,SPH-200G,SPH-200V,SPH-200T,SOR-300G,SOR-400G,SOR-400V

Samsan pH meter, SPH/SOR model for accurate pH measurement Easy maintenance Suitable for use with drugs Biotechnology, cosmetics, food, beverages, chemistry, experiments for studying

SPECIFICATIONS DATA SAMSAN SPH Series

SAMSAN SPH-100G,SPH-100T,SPH-200G,SPH-200V,SPH-200T

 

MODEL SPH-100G SPH-100T SPH-200G
Type Filling Filling Non-Filling
Measuring Range 0-14.00pH 0   ̴ 14.00 pH 0   ̴ 14.00 pH
Conductivity of liquid over than 100 0㎲/㎝ over than 100 us/cm over than 100 us/cm
Temperature 5-60°C 5 – 60˚C 0 – 90˚C
Pressure Using HOLDER filled with KCL It’s filled by atomospheric pressure Using HOLDER filled with KCL It’s filed by atomospheric pressure Less than max 1kg/cm²
Reference Electrode Ag/AgCl Ag/AgCI Ag/AgCI
Junction sleeve sleeve sleeve
Zero Potential 7.00pH±0.01pH 7.00pH ± 0.01pH 7.00pH ± 0.01pH
Materials glass glass glass
Dimensions Ø12 X 155mm Ø12 X 155mm Ø12 X 155mm
Cable Length 5M(Standard) 5m (Standard) 5m (Standard)
Connector Y-Terminal Type Y-Terminal type Y-Terminal type
Connector Y-Terminal type Available Y-Terminal type

 

MODEL SPH-200V SPH-200T
Type Non-Filling Non-Filling
Measuring Range 0   ̴ 14.00 pH 0   ̴ 14.00 pH
Conductivity of liquid over than 200 us/cm over than 200 us/cm
Temperature 0 – 80˚C 0 – 90˚C
Pressure Less than max 0.5kg/cm² Less than max 1kg/cm²
Reference Electrode Ag/AgCI Ag/AgCI
Junction Ceramic sleeve
Zero Potential 7.00pH ± 0.01pH 7.00pH ± 0.01pH
Materials PC Housing glass
Dimensions Ø12 X 155mm Ø12 X 155mm
Cable Length 5m (Standard) 5m (Standard)
Connector Y-Terminal type Y-Terminal type
Connector Y-Terminal type Available

 

SPECIFICATIONS DATA SOR Series

SAMSAN SOR-300G,SOR-400G,SOR-400V

 

ITEM ORP electrode ORP electrode ORP electrode
MODEL SOR-300G SOR-400G SOR-400V
Type Filling Non-Filling Non-Filling
Measuring Range ± 1500 mV ± 1500 mV ± 1500 mV
Conductivity of liquid over than 100 us/cm over than 200 us/cm over than 200 us/cm
Temperature 0 – 60˚C 0 – 90˚C 0 – 80˚C
Pressure Using HOLDER filled with KCL It’s filed by atomospheric pressure Less than max 1kg/cm² Less than max 0.5kg/cm²
Reference Electrode Ag/AgCI Ag/AgCI Ag/AgCI
Junction sleeve sleeve Caramic
Zero Potential 0 mV ± 1 mV 0 mV ± 1 mV 0 mV ± 1 mV
Materials glass glass PC Housing
Dimensions Ø12 X 155mm Ø12 X 155mm Ø12 X 155mm
Cable Length 5m (Standard) 5m (Standard) 5m (Standard)
Connector Y-Terminal type Y-Terminal type Y-Terminal type
Connector Y-Terminal type Y-Terminal type Y-Terminal type